R32 Dual-Fan Monoblock High-Power Series Air-Source Heat Pump JM220HC3N

Multifunction, High-Efficiency, 22kW

The R32 Dual-Fan Monoblock Low-Power Series Air-Source Heat Pump redefines home climate control with its impressive combination of energy efficiency, reliability, and advanced features. Ideal for residential and light commercial applications, this heat pump ensures your indoor environment is always perfect.

an icon of the TUV certificate 01
an icon of the SGS certificate 01
an icon of the ISO certificate 01
an icon of the etl certificate 01


Inverter Heat Pump 22 kW JM220HC3N Efficiency Chart

Ambient Temp.(Dry Bulb temp.)-25-20-15-7271520253543
Heating Capacity (W)
(Outlet Water Temp. 55℃)
9382107221213214424 17628 20505 21630 22116 22731 23379 24921 
Heating Capacity (W)
(Outlet Water Temp. 41℃)
9431108021229915162 17721 21213 21760 22163 23081 24502 25819 
Heating Capacity (W)
(Outlet Water Temp. 35℃)
9541113211249215294 17871 21528 21891 22371 23518 24663 25913 
Power Input (W)
(Outlet Water Temp. 55℃)
6488652066106725 7188 7286 7307 6955 6532 5979 5755 
Power Input  (W)
(Outlet Water Temp. 41℃)
4879498150535216 5432 5608 4989 4607 4489 4481 4381 
Power Input (W)
(Outlet Water Temp. 35℃)
4581469147734871 5088 4986 4452 4326 4291 4287 4276 
COP
(Outlet Water Temp. 55℃)
1.45 1.64 1.84 2.15 2.45 2.81 2.96 3.18 3.48 3.91 4.33 
COP
(Outlet Water Temp. 41℃)
1.93 2.17 2.43 2.91 3.26 3.78 4.36 4.81 5.14 5.47 5.89 
COP
(Outlet Water Temp. 35℃)
2.08 2.41 2.62 3.14 3.51 4.32 4.92 5.17 5.48 5.75 6.06 
Water production(kg/h)
(Water temp15~55℃)
201.68 230.48 260.79 310.06 378.93 440.78 464.96 475.41 488.63 502.56 535.71 


Heating Capacity Curve at Different Ambient Temperatures

Heat Capacity curve of 22kW at different ambient temperatures


COP Curve Graph at Different Ambient Temperatures

COP of 22kW at different ambient temperatures


Water Production (kg/h) Curve Graph at Different Ambient Temperatures

Water production of 22kW at different ambient

Parameters

ModelJM220HC3N
HeatingHeating Capacity (kW)22
(A7/6℃,W30/35℃)Power Input (kW)5.13
 COP4.29
HeatingHeating Capacity (kW)14.6
(A-12℃,W36/41℃)Power Input (kW)5.77
 COP2.53
HeatingHeating Capacity (kW)21.8
(A7/6℃,W40/45℃)Power Input (kW)6.23
 COP3.5
HeatingHeating Capacity (kW)21.3
(A7/6℃,W47/55℃)Power Input (kW)7.15
 COP2.98
CoolingCooling Capacity (kW)17.8
(A35/24℃,W23/18℃)Power Input (kW)4.97
 EER3.58
CoolingCooling Capacity (kW)13.5
(A35/24℃,W12/7℃)Power Input (kW)4.95
 EER2.73
Max Input Power (kW)6.9
Maximum Input Current - with E-Heat (A)12.3
Wifi ControlYes
ControllerLED
Power Supply380V~415V/50Hz/60Hz
Operating Air Temp.(℃)-25~43
Max.Outlet Water Temp(℃)55
RefrigerantR32
Fan Quantity2
Compressor BrandPanasonic (Rotary)
Brand of EEVSANHUA
Brand of 4-way valveSANHUA
Heat ExchangerPlate Heat Exchanger
Casing MaterialGalvanized Sheet
Water Pipe Connection (inch)G1"(female thread)
Noise Level at 1m dB(A)56
Water Flow (m³/h)3.78
Water Pressure Drop (kPa)20
Min/Max heating water pressure (bar)2.0/10.0
Net Dimensions ( L/W/H ) mm1127/475/1360
Package Dimensions ( L/W/H ) mm1195/535/1510
Net Weight KG120
Gross Weight KG145
Loading quantity 20GP/40GP,40HQ pcs22/48/48

FAQs

The “R32 Dual-Fan Monoblock High-Power Series Air-Source Heat Pump” is a high-performance heating and cooling solution designed for larger residential and commercial spaces.

The dual-fan monoblock design optimizes airflow and heat exchange, enhancing the heat pump’s efficiency and performance even in demanding conditions.

The “R32 High-Power Series Heat Pump” offers substantial heating and cooling capacities, making it ideal for spaces that require consistent temperature control.

This series covers a wide range of heating and cooling capacities, catering to larger residential homes and various commercial applications.

Heating Capacity : 12.8 ~ 32 kW
Cooling Capacity: 13 ~ 24 kW

The utilization of R32 refrigerant contributes to a lower environmental impact due to its lower global warming potential (GWP) compared to traditional refrigerants.

Get In Touch with Us