R290 Indoor Fresh Air Heat Pump with Heat Recovery

Indoor Dual Air Source Monobloc Heat Pump

The JNOD R290 fresh air heat pump combines space heating, cooling, domestic hot water, fresh air ventilation and exhaust air heat recovery in one integrated indoor system.

Using energy from both outdoor air and indoor exhaust air, this dual air source heat pump provides a flexible solution for residential projects requiring water-based heating, hot water and fresh air management.

Key Features: R290 Refrigerant | Up to 350 m³/h Ventilation | F5 + F9 Filtration | Flexible Tank Configurations

MCS certification heatpump logo
an icon of the TUV certificate 01
an icon of the SGS certificate 01
an icon of the ISO certificate 01
CE certification heatpump logo
keymark certification heatpump logo
One Heat Pump, Multiple Home Comfort Needs

One Fresh Air Heat Pump, Five Comfort Functions

The JNOD fresh air heat pump combines heating, cooling, domestic hot water, fresh air supply and ventilation in one indoor system, providing year-round comfort for residential applications.

Dual Air Source Technology & Heat Recovery

Dual Air Source Technology & Heat Recovery

The system extracts thermal energy from outdoor air for heating while recovering heat from indoor exhaust air. This dual air source design integrates heat pump operation with ventilation heat recovery.

Advanced Fresh Air & Filtration

Fresh Air Ventilation with F5 + F9 Filtration

With up to 350 m³/h ventilation airflow and F5 + F9 dual-stage filtration, the system supports filtered fresh air supply. Integrated sensors support ventilation monitoring and safety functions.

R290 Heating Technology & Key Components

R290 Heating Technology & Key Components

Featuring R290 refrigerant, a DC inverter twin-rotary compressor and a plate heat exchanger, the system supports heating, cooling and hot water production, with outlet water temperatures of up to 75°C under specified conditions.

Heat Pump IoT Control Workspace

Smart IoT Monitoring & System Control

The integrated IoT platform supports connected system monitoring. The product brochure also lists SG Ready, dual-zone functionality and mixing valve features for different heating configurations.

Fresh Air Heat Pump Split Design for Flexible Spaces

Flexible Indoor Installation for Low-Ceiling Spaces

The separate-tank design allows the main unit and water tank to be installed in different locations, offering flexible installation in utility rooms, under-stair spaces and other compact indoor areas.

Modern Utility Room with All in one Fresh Air Heat Pump Built in 150L Water Tank

All-in-One Design with a Built-in 150 L Water Tank

The all-in-one configuration integrates a 150 L water tank within the heat pump unit, reducing the need for separate equipment placement and simplifying indoor system layout.

JNOD Combi Fresh Air and Ventilation Modes

Fresh Air Option & Ventilation Mode

Fresh Air Option: Combines heat recovery with fresh air preheating, precooling and dehumidification.

Ventilation Mode: Focuses on exhaust air heat recovery and ventilation.

Both configurations offer different airflow arrangements to suit project requirements

Heat Pump Solutions for Multiple Comfort

Outstanding-Efficiency

Low-Noise

Smaller Carbon Footprint

WIFI Built-In

75°C High-Outlet Water

Easy Installation

Technical Specifications

ModelJMU40HV-FJUU40HVJUU70HV
Heating Capacity4kW4kW7kW
Version DifferenceFresh Air version
(Heat Recovery&Fresh preheat、precool、Dehumidification)
Ventilation version
(Heat Recovery only)
Ventilation version
(Heat Recovery only)
Power supply220V-240V~ 50Hz/60Hz220V-240V~ 50Hz/60Hz220V-240V~ 50Hz/60Hz
Max. power input (W) (under boost mode)276027604600W
Max. current input (A) (under boost mode)12A12A20A
Heating 1Heating capacity1500~4505W1500~4505W3000~7050W
Rated power input270~1098W270~1098W500~1658W
COP4.10~5.554.10~5.554.25~5.55
Heating 2Heating capacity1200~3680W1200~3680W3000~7070W
Rated power input296~1363W296~1363W700~2525W
COP2.70~4.052.70~4.052.80~4.20
CoolingCooling capacity900~2786W900~2786W2000~4500W
Rated power input276~1114W276~1114W700~1800W
EER2.50~3.252.50~3.252.50~3.45
Seasonal Space Heating Energy efficiency ClassWater outlet temperature 35℃A+++A+++A+++
Water outlet temperature 55℃A++A++A++
SCOPSCOP (Water Temp. At 35℃)4.45 4.45 4.50 
SCOP (Water Temp. At 55℃)3.35 3.35 3.45 
Operating Ambient Temp.Heating-25-43℃-25-43℃-25-43℃
Cooling16-43℃16-43℃16-43℃
DHW-25-43℃-25-43℃-25-43℃
Outlet Water Temp.Heating20-75℃20-75℃20-75℃
Cooling12-25℃12-25℃12-25℃
DHW20-70℃20-70℃20-70℃
RefrigerantR290R290R290
Sound power level 48 dB(A)48 dB(A)48 dB(A)
Degree of protection(with air inlet and outlet ducts)IPX4IPX4IPX4
Anti-electric shock classⅠⅠⅠ
Monoblock
HP Unit
Water Piping ConnectionsG1'External threadG1'External threadG1'External thread
Net Dimensions (L/W/H)636*668*1220636*668*1220664*762*1438
Package Dimensions (L/W/H)700*730*1338700*730*1338600*700*1320
Net Weight138kg138kg146
Gross Weight160kg160kg168
Water TankConfiguration TypeIndirectly heated storage tankDirectly heated storage tank Floor-standing base
ModelT150GNT120G 
ColorWhiteWhiteWhite
Expansion Tank150L120L 
Water ConnectionG1'G1'G1'
Net Dimensions (L/W/H)636*668*1090636*668*1090636*668*500
Package Dimensions (L/W/H)700*730*1215700*730*1215 
Net Weight81kg81kg42kg
Gross Weight103kg103kg64kg

FAQs

The system is designed to support heating, cooling, domestic hot water, fresh air and ventilation. Available operating combinations depend on the selected configuration.

The system extracts energy from outdoor air and recovers heat from indoor exhaust air, combining heat pump operation with ventilation heat recovery.

Yes. The brochure illustrates a separate-tank arrangement for low-ceiling and space-limited indoor installations. Actual dimensions and connection requirements must be checked for the selected model.

The product brochure specifies ventilation airflow of up to 350 m³/h. The available airflow under actual installation conditions depends on the system configuration and duct resistance.

Get In Touch with Us